FORGOT YOUR DETAILS?

CREATE ACCOUNT

GSMAlert for Scanners

GSM Alert system from G-Tek is a versatile alert system to inform about the event through SMS and voice over GSM network. It can take up to 15 potential free inputs and on alert can inform up to 20 nos.

GSM alert system can be easily integrated to your existing system if you have one potential free contact.Since GSM Alert System has, a common to all relay output, the buzzer or hooter connected to your existing system can be transferred here for seamless performance.

Configuration of Alerts, Message for alert, recording of voice, priority of alerts all are fully programmable using USB interface. It has a built-in memory to store the time of occurrence of the alert, when the SMS/Voice was send and to whom it was successful / not successful.

The memory is a rollover type and it can store up to last 1500 events. Standard / 21CFR Part II compliant GSMViewLogTM is a perfect companion for statutory compliance.

Category:

Features

  • Signal strength checking
  • Up to 20 contact numbers
  • Up to 15 alert messages and 4 different voice calls
  • Settable Alert priority
  • Field programmable message strings and voice recording
  • Alert log details
  • Remote Arming, Disarming and Partial Disarming
  • External Battery Backup
  • Rollover memory
  • Relay output for connecting to hooter
  • LED status indicators

Specification

Model No GSM Alert System
Product Code 7xxxxxx
Input
No of Alert inputs 5 / 10 /15
Type of input Potential free contact
Voice and Messaging
Mobile System GSM
No of Mobile Phones where SMS / Voice messages can be send 5/ 10/ 15/ 20
Setting of Mobile Nos User Configurable
Alert messages User Configurable
SMS Alerts Each Maximum of 135 characters long
Voice Recording Through Built-in Microphone
No of Voice Messages 1/ 2/ 3/ 4
Arming / Disarming / Partial Arming Through SMS
Display and Operator Panels
Display Type LED for status and Error
Status Indicator Status –

Network – Healthy / Failure

Health – Device health

Panel Keys Two Keys to Test the System and Reset the Alarm condition
Environmental
Temperature (Operation)5˚C to 45˚C
(Limiting) 0˚C to 50˚C
(Storage)-20˚C to 60˚C
Humidity (Operation) 10 to 80 % RH Non Condensing
(Storage) 5 to 90 % RH Non Condensing
Altitude <2000 meter
Power Requirement
Supply Voltage (Mains Operated through adapter) 85-265VAC 47-63Hz
Battery backup Yes
DC Adapter Operated Yes
Power 12W Max With Maximum Configuration
Fuse Type None
USB
Communication USB 2.0
Protocol Proprietary
Battery Backup
Battery 4×1.5V AA Ni-MH rechargeable battery
Battery Charger Yes; Built–in with Overcharge, Over temperature; Over discharge protected
Battery Reverse Polarity Protected
Minimum Back up 18 Hrs.
General
Termination Non Interchangeable , Removable Plugs, Individual For Each Input
Data Storage Non Volatile Flash Memory For Parameter and data Storage
No of Data Storage Last 512 / 1024 / 1536 records of error logs
Safety
Safety IEC 61010-1
Pollution Degree II
Installation Category II
Vibration NA
Shock NA
Relay Output Details
No of Relay Output 1
Output Type 1 Form C
Life expectancy Mechanical:10^7 operations
Electrical: 10^5 operations
Load 1A, 230VAC resistive
Relay refresh rate Common to all; On occurrence of Alert and remains ON until reset
Isolation Relay – Relay 2.5 KV 1 Minute
Isolation Relay Contact – GND 1.5 KV 1 Minute
Overall Dimension
Dimension L x W x D (mm) 200x90x35

*Features depends on the options ordered; Specifications are subject to change without notice

Accessories

1. 15 V DC 1.2Amp Adapter
    Part No.: 200661

 

2. Ethernet Cable

    Part No.: 236249

 

3. USB Cable

    Part No.: 210027

4. GSM Rubber Duck 5 dB Antenna; Frequency Range: 800-1900 MHz

Part No.: 200477

Downloads

    Inquire Now

    TOP