The series SC9x of data logger is a high-speed data logger. They incorporate the proven ratiometric16 bit ADC for high accuracy and resolution. 4×20 characters backlit LCD display with white over blue characters make it visible from the distance.

These data loggers measure up to 24 channels of any process parameters or standard RTD and Thermocouple inputs. Scan rate of 12 channels per 5 seconds, makes it very useful for validation of any process. With internal memory for storing data, it helps store validation parameters and retrieve them later for generating reports.

These data loggers along with AqWireTM series of Software makes a complete solution for 21CFR Part II compliance. Various industry specific validation reports are built-in to the software. This makes it very easy for the user to meet the qualification / validation requirements of the certifying agencies and meeting various quality standards. User defined Password protected menus does not allow any unauthorized changes either from PC or from key-board. Every changeis reported either online or in offline mode.

It has an option of communication like RS232C, RS485, USB or TCP/IP. It alsosupports MODBUS ASCII protocol. When used over TCP/IP, it can easily form a part of the large networked data logger. It also supports G-Tek’sgtekNetTM web based software.

Category:

Features

  • Up to 24 channels
  • High Scan rate of 12 channels in 5 seconds
  • Built-in non-volatile memory of up to 1MB.
  • The online printing and storing is possible from 5 seconds up to 18 hours.
  • Individual High low alarm setting
  • User settable Resolution up to 0.0001
  • 21CFR Part II compliance
  • USB Connectivity

Specification

  • Up to 24 channels
  • High Scan rate of 12 channels in 5 seconds
  • Built-in non-volatile memory of up to 1MB.
  • The online printing and storing is possible from 5 seconds up to 18 hours.
  • Individual High low alarm setting
  • User settable Resolution up to 0.0001
  • 21CFR Part II compliance
  • USB Connectivity
Specifications:
Model SC9x 
Product Code 9x…
Display and Operator Panels
Display Type 4×20 Characters backlit LCD display white over blue
Status Indicator Store LED, Heart Beat LED, Alarm High/Low Indication
Panel Keys Front panel KB consisting of 4 keys for programming and configuration setting
Analog Input Details
No Of Inputs 8/16/24 Channels
TC Types J, K, R, S, T
RTD PT-100; DIN 43760; α=0.00385
Volt 0-1V DC
mA 4-20mA; 0-20mA (External Shunt Resistance of 50 Ω 0.1%)
Sensor Type and Range Refer to the Table 2
Accuracy
Accuracy Refer to the Table 2
Linearization Polynomial Based Software Linearization
Resolution user settable upto 0.0001
CJC Error ±0.5˚C for 0-50˚C
Data Scan Rate 12 Channel/5Sec
Protection
Input Impedance RTD/TC /Volt > 20 MΩ
Input Impedance mA 50Ω Shunt External
CMRR >100 dB@ 50, 60 Hz at 3 Sample per Second
NMRR >50 dB@ 50, 60 Hz at 3 Samples per Second
Maximum Common Mode Voltage 5V AC
Isolation Channel – EARTH 2.5KV, 1 Minute
Input Protection 30V AC/DC Max
Batch Storage / Data Memory Details
Start / Stop Key Press / Remote Start – Stop
Store Interval 5 Seconds to 18 Hrs
Memory Size 1 MB / Stop on Full / Rollover
General
Termination Non Interchangeable, Removable Plugs, Individual For Each Input
Max No Of Input Cards Per Device 3 (8 channels each)
Password Protection Optional
Data Storage Refer to Table 1
Environmental
Temperature (Operation)5˚C to 45˚C
(Limiting) 0˚Cto 50˚C
(Storage)-20˚Cto 60˚C
Humidity (Operation)10 to 80 % RH Non Condensing
(Storage)5 to 90 % RH Non Condensing
Altitude <2000 meter
Power Requirement
Supply Voltage (Mains Operated) 85-264VAC 47-63Hz
Power 15W Max With Maximum Configuration
Transmitter Power Supply
No of outputs available 1
Voltage 12-15V DC
Max Load current 30mA
Short circuit protection Yes
Isolation NA
Communication
Printer Port (Optional) Centronics
Communication EIA Rs485 2 wire / RS232
Protocol Proprietary
Baud Rate 9600/19200
Parity None
Device Address Yes, User Settable
USB Device Mode/Host Mode
LED Indication Yes
Relay Output Details
No of Relays 1 / 8 Relays
Max. no. of Relay 8
Max. no. of relay group 8 (any channel/set-point can be assigned to any group)
Output Type Potential Free Contact; 1 Form C
Alarm Set-point High/Low individually settable for each channel
Life Expectancy Mechanical: 107 operations
Electrical: 105 operations
Relay Contact 1A 230VAC resistive
Relay Refresh Rate 5 Sec
Isolation Relay-Relay 2.5KV 1 Minute
Isolation Relay contact – GND 1.5KV 1 Minute
Overall Dimension
Dimension L x W x D (mm) 210 x 192 x 96
Data Storage:
No. of records that can be stored in the Memory
Channels No. of Records
8 3600
16 1900
24 1250
Table 2 : Sensor Type, Range, Accuracy, Temp Specification:
Sensor Range Accuracy Temp. Drift @25°C
RTD (Pt-100) -200 to 850°C ± 0.05% FSD 0.0016 % / °C
0-1V ± 3000.0 ± 0.03% FSD 0.0019 % / °C
4-20mA ± 3000.0 ± 0.03% FSD 0.0019 % / °C
0-20mA ± 3000.0 ± 0.03% FSD 0.0019 % / °C
J type TC 0 to +750 ±0.1% FSD 0.0016 % / °C
K type TC 0 to +1350 ±0.2% FSD 0.0016 % / °C
R type TC 0 to +1700 ± 0.1% FSD+
(± 0.4% for 0-100°C) 0.0016 % / °C
(± 0.2% for 100-200°C)
(± 0.2% for 1600-1700°C)
S type TC 0 to +1700 ± 0.1% FSD+
(± 0.3% for 0-100°C) 0.0016 % / °C
(± 0.2% for 100-200°C)
T type TC -200 to +400 ± 0.1% FSD 0.0016 % / °C

1. Panel Mounting Clamps: 2 numbers

    Part No. 210034

2. Ethernet Cable

    Part No. 236249

3. USB Cable

    Part No. 210027

  

4. RS232-C Cable

    Part No. 121011

  

5. RS485 TO 232 Converter

    Part No. 420114

    

6. RS232 TO TCP/IP Converter

    Part No. 200572

  

Please Login first to access download section





Accessories

  • Up to 24 channels
  • High Scan rate of 12 channels in 5 seconds
  • Built-in non-volatile memory of up to 1MB.
  • The online printing and storing is possible from 5 seconds up to 18 hours.
  • Individual High low alarm setting
  • User settable Resolution up to 0.0001
  • 21CFR Part II compliance
  • USB Connectivity
Specifications:
Model SC9x 
Product Code 9x…
Display and Operator Panels
Display Type 4×20 Characters backlit LCD display white over blue
Status Indicator Store LED, Heart Beat LED, Alarm High/Low Indication
Panel Keys Front panel KB consisting of 4 keys for programming and configuration setting
Analog Input Details
No Of Inputs 8/16/24 Channels
TC Types J, K, R, S, T
RTD PT-100; DIN 43760; α=0.00385
Volt 0-1V DC
mA 4-20mA; 0-20mA (External Shunt Resistance of 50 Ω 0.1%)
Sensor Type and Range Refer to the Table 2
Accuracy
Accuracy Refer to the Table 2
Linearization Polynomial Based Software Linearization
Resolution user settable upto 0.0001
CJC Error ±0.5˚C for 0-50˚C
Data Scan Rate 12 Channel/5Sec
Protection
Input Impedance RTD/TC /Volt > 20 MΩ
Input Impedance mA 50Ω Shunt External
CMRR >100 dB@ 50, 60 Hz at 3 Sample per Second
NMRR >50 dB@ 50, 60 Hz at 3 Samples per Second
Maximum Common Mode Voltage 5V AC
Isolation Channel – EARTH 2.5KV, 1 Minute
Input Protection 30V AC/DC Max
Batch Storage / Data Memory Details
Start / Stop Key Press / Remote Start – Stop
Store Interval 5 Seconds to 18 Hrs
Memory Size 1 MB / Stop on Full / Rollover
General
Termination Non Interchangeable, Removable Plugs, Individual For Each Input
Max No Of Input Cards Per Device 3 (8 channels each)
Password Protection Optional
Data Storage Refer to Table 1
Environmental
Temperature (Operation)5˚C to 45˚C
(Limiting) 0˚Cto 50˚C
(Storage)-20˚Cto 60˚C
Humidity (Operation)10 to 80 % RH Non Condensing
(Storage)5 to 90 % RH Non Condensing
Altitude <2000 meter
Power Requirement
Supply Voltage (Mains Operated) 85-264VAC 47-63Hz
Power 15W Max With Maximum Configuration
Transmitter Power Supply
No of outputs available 1
Voltage 12-15V DC
Max Load current 30mA
Short circuit protection Yes
Isolation NA
Communication
Printer Port (Optional) Centronics
Communication EIA Rs485 2 wire / RS232
Protocol Proprietary
Baud Rate 9600/19200
Parity None
Device Address Yes, User Settable
USB Device Mode/Host Mode
LED Indication Yes
Relay Output Details
No of Relays 1 / 8 Relays
Max. no. of Relay 8
Max. no. of relay group 8 (any channel/set-point can be assigned to any group)
Output Type Potential Free Contact; 1 Form C
Alarm Set-point High/Low individually settable for each channel
Life Expectancy Mechanical: 107 operations
Electrical: 105 operations
Relay Contact 1A 230VAC resistive
Relay Refresh Rate 5 Sec
Isolation Relay-Relay 2.5KV 1 Minute
Isolation Relay contact – GND 1.5KV 1 Minute
Overall Dimension
Dimension L x W x D (mm) 210 x 192 x 96
Data Storage:
No. of records that can be stored in the Memory
Channels No. of Records
8 3600
16 1900
24 1250
Table 2 : Sensor Type, Range, Accuracy, Temp Specification:
Sensor Range Accuracy Temp. Drift @25°C
RTD (Pt-100) -200 to 850°C ± 0.05% FSD 0.0016 % / °C
0-1V ± 3000.0 ± 0.03% FSD 0.0019 % / °C
4-20mA ± 3000.0 ± 0.03% FSD 0.0019 % / °C
0-20mA ± 3000.0 ± 0.03% FSD 0.0019 % / °C
J type TC 0 to +750 ±0.1% FSD 0.0016 % / °C
K type TC 0 to +1350 ±0.2% FSD 0.0016 % / °C
R type TC 0 to +1700 ± 0.1% FSD+
(± 0.4% for 0-100°C) 0.0016 % / °C
(± 0.2% for 100-200°C)
(± 0.2% for 1600-1700°C)
S type TC 0 to +1700 ± 0.1% FSD+
(± 0.3% for 0-100°C) 0.0016 % / °C
(± 0.2% for 100-200°C)
T type TC -200 to +400 ± 0.1% FSD 0.0016 % / °C

1. Panel Mounting Clamps: 2 numbers

    Part No. 210034

2. Ethernet Cable

    Part No. 236249

3. USB Cable

    Part No. 210027

  

4. RS232-C Cable

    Part No. 121011

  

5. RS485 TO 232 Converter

    Part No. 420114

    

6. RS232 TO TCP/IP Converter

    Part No. 200572

  

Please Login first to access download section





Please first to access download section

Downloads

Order

TOP