Storage Recorder – CR2010 series BBR Pro 6
CR2010 series BBR Pro 6” Circular Chart Recorder
The most popular 6” circular chart recorder of CR2010 series, is also available with an internal memory of 64KB to store data up to 14 days at 5minutes store interval. This recorder is specifically tailored to monitor the blood bank refrigerator temperature data.
This recorder also has an input for Door Open switch. Since door opening and closing is very frequent during the removal of the stored blood, it is very easy to monitor how often and for how much time the door was left open with this recorder.
This recorder uses pressure sensitive chart paper so there is no need to replace the pen. The smudging of the ink is also not there, besides since the paper used is pressure sensitive instead of thermal, the life of the recording is very high. Mains failure and return is also logged.
The user can download, view, analyze and generate the reports for data, events like power failure, door open and close etc by BBRChartTM software interface via USB.The recorder comes with a built-in battery back up to ensure the proper working in case of power failure. Most other features are similar to the standard CR2010 series 6” recorder.
Features
- 6” Chart Width
- Inkless chart recorder
- LCD Display
- Real Time Clock
- Data Storage 64KB of memory
- Event Logging like Power Fail / Door Open / Power Restore
- storage of 14 days of data at 5 minute store interval
- USB port to communicate with PC
- BBR-Chart Application to download data
- Generate Reports from BBR-Chart
- Single Analog Input channel
- Direct Input standard PT-100 sensor
- Chart Speed of 7D/Rev
- Universal Power Supply 85-264 V AC, 47-63 Hz
- Battery Backup up to 72 hours
Specification
Model No | CR2010 Series; BBR Chart Recorder |
Product Code* | 27×03 |
Recording System | |
No. of Pens | 1 – Suitable for marking on Pressure Sensitive Paper |
Pen Marking | Continuous |
Pen Response Time | <5Sec (Full Scale) |
Pen Resolution | Stepper Motor Controlled better than 0.1% FSD |
Overshoot | None |
Chart | |
Chart Speed | 7D/Rev |
Chart Calibrated Radius | 2.3″ (approx. 59mm) |
Chart Ranges | Programmable |
Display, Operator Panels and Input | |
Display Type | 3½ digit LCD |
Status Indicator | RTC, Batch Status, Battery Status |
Panel Keys | Front panel KB consisting of 3 keys for programming and calibration |
Analog Input | RTD PT-100 |
Sensor Type and Range | Refer to Table 1 |
Scan Rate | Continuous 1 reading per second |
Memory | |
Memory Size | 64KB |
Data Storage | Up to 14 days at 5min Store Interval |
Alarm Records | Yes (Going out of limit and coming back to limit is considered as one alarm record) |
Record for Door Open / Close | Yes |
Mains Failure Record | Yes |
Memory Type | Cyclical – Most recent data is always available |
User Settable Parameters for Recording | |
Alarm Condition Occurrence Time Delay | 1 to 99 mins; user settable (through PC)
When the temperature remains out of limit for more than set time then only the alarm condition is assumed. |
Real Time Clock (RTC) | Settable from Keyboard in DD/MM/YY/HR/MN format |
Door Open/Close | Input through Potential Free contact. |
Communication | |
Communication Type | USB 2.0 |
PC Application | BBR-Chart TM to download data; Configure recorder and generate report. |
Protection | |
Input Impedance | > 20 MΩ |
CMRR | >100 dB@ 50, 60 Hz at 3 Sample per Second |
NMRR | >50 dB@ 50, 60 Hz at 3 Samples per Second |
Maximum Common Mode Voltage | 5 V AC |
Isolation Channel – Earth | 1.5KV 1 minute |
Isolation Channel – Channel | NA |
Input Protection | 30 V AC/DC max |
Termination | Non interchangeable, Removable Plugs |
Environmental | |
Temperature | (Operation)5˚C to 45˚C |
(Limiting) 0˚C to 50˚C | |
(Storage)-20˚C to 60˚C | |
Humidity | (Operation) 10 to 80 % RH Non-Condensing |
(Storage) 5 to 90 % RH Non-Condensing | |
Altitude | <2000 meter |
Power Requirement |
|
Supply Voltage (Mains Operated) | 85-264 V AC 47-63Hz |
Battery backup | Yes |
DC Adapter Operated | Yes |
Power | 15 W Max with Maximum Configuration |
Fuse Type | None |
Battery Backup | |
Battery | 7 Ah 12 V, 1.4 A External Lead Acid Battery |
Battery Charger | Yes |
Battery Reverse Polarity | Protected |
Minimum Back up | >72 Hours |
Safety | |
Safety | IEC 61010-1 |
EMI-EMC | EN 61326-1 Class A |
Pollution Degree | II |
Installation Category | III |
Vibration | 2g Peak (10 Hz-150Hz) |
Shock | IEC61010-1 |
IP Rating | IP50 (Door and Bezel only) |
Overall Dimensions | |
Dimension (L x W x D) mm | 232x205x117 |
Panel Cutout (L x W) mm | 198×169 |
Bezel (L x W) mm | 232×205 |
*Actual specification may vary depending on the optional features installed.
**Refer to the back panel of recorder for exact rating.
Table 1 Sensor Type, Range, Accuracy and Max Error Specification
Input Type | Valid Input Range | Resolution Chart | Accuracy |
PT-100(RTD) | -100 to +600˚C | 2% | +/- 0.5% FSD |
Table 2 Chart type of Chart Recorder
Sr. No. |
Range** |
Speed |
Size |
Part No. |
Part Description |
21 | 0 to +100 | 24H | 6” | 304001 | D60100 |
22 | 0 to +150 | 24H | 6” | 304002 | D60150 |
23 | 0 to +200 | 24H | 6” | 304005 | D60200 |
24 | 0 to +300 | 24H | 6” | 304008 | D60300 |
25 | -50 to +50 | 24H | 6” | 304016 | D6-50+50 |
26 | 0 to +160 & -1 to 3 | 24H | 6” | 304004 | D60160&-1+3 |
27 | +90 to +140 | 4H | 6” | 305001 | 4H90140 |
28 | 0 to +100 | 7 Day | 6” | 307001 | W60100 |
29 | -50 to +50 | 7 Day | 6” | 307010 | W6-50+50 |
30 | +50 to -50 | 7 Day | 6” | 307009 | W650-50 |
31 | -100 to +50 | 7 Day | 6” | 307005 | W6-100+50 |
32 | +50 to -100 | 7 Day | 6” | 307008 | W650-100 |
33 | +40 to -10 | 7 Day | 6” | 307007 | W640-10 |
34 | 0 to +50 | 7 Day | 6” | 307004 | W6050 |
35 | 0 to +10 | 7 Day | 6” | 307012 | W6010 |
36 | +20 to -10 (PS) | 7D | 6” | 308009 | W620-10PS |
37 | +50 to -100 (PS) | 7D | 6” | 308008 | W650-100PS |
39 | +40 to -10 (PS) | 7D | 6” | 308003 | W640-10PS |
40 | -50 to + 50 (PS) | 7D | 6” | 210042 | W6-5050PS |
50 | Other Please Specify |
** First value in the chart is at the center of the Chart.
** Chart range low and chart speed are fixed as per the order code.
# PS: Pressure Sensitive Chart