Strip Chart Recorder – STC 1P-2P
SR2000 series of STRIP chart recorders are available for recording one or two process parameters simultaneously. The strip chart recorder is very useful when you want to monitor your process unattended. These recorders are widely used in process industry for monitoring of various processes like annealing, curing, hydro testing etc.
It takes direct inputs from RTD Pt-100 / Thermocouples / process inputs like 4-20mA / 0-20mA / 0-1V. Standard chart speed varies from 10 mm/Hr to 3600 mm/Hr. These recorders are microcontroller based. Crystal controlled chart drive ensures accurate chart speed. Stepper motors for both pen and chart drive ensures no lag and backlash.
A cutout of 138x138mm makes it a perfect fit for replacing any of your existing recorders of any make. Transparent polycarbonate door window makes the chart visible from distance. They come with a universal power supply as a standard feature. Other power supply inputs are also available.
Features
- 100mm chart Width
- One to Three Analog Input channels
- Universal Power Supply 85-264 V AC, 43-65 Hz
- Other power supply inputs on request
- Direct Input standard Pt-100 / Thermocouple sensors
- Process Input through 4-20mA /0-20mA / 0-1V
- 10-3600 mm/hr of chart speed
- Other chart speed available on request
Specification
- 100mm chart Width
- One to Three Analog Input channels
- Universal Power Supply 85-264 V AC, 43-65 Hz
- Other power supply inputs on request
- Direct Input standard Pt-100 / Thermocouple sensors
- Process Input through 4-20mA /0-20mA / 0-1V
- 10-3600 mm/hr of chart speed
- Other chart speed available on request
Pens | |
No. of Pens | 1/2 |
Pen Marking | Continuous |
Pen Response Time | <5Sec (Full Scale) |
Pen Resolution | Stepper Motor Controlled better than 0.1% FSD |
Overshoot | None |
Chart | |
Chart Speed | 10 mm/ hour to 3600mm/hour |
Chart Calibrated Radius/Size | 100mm |
Chart Ranges | Standard (Refer Table 2) / Customized* |
Display, Operator Panels and Input | |
Display Type | Digital, 8 digit ultra-bright LED Numeric / semi alphabetic |
Display Height | 0.3” |
Status Indicator | Channel number and corresponding parameter values, prompts and messages displayed for ease of setup and programming. |
Panel Keys | Front panel KB consisting of 3 keys for programming and calibration |
Analog Input | RTD PT-100 / 4-20mA (External Shunt Resistance of 50 Ω 0.1%) / TCJ-K-R-S-T/ 0-1V |
Sensor Type and Range | Refer to the Table 1 |
Scan Rate | Continuous 1 reading per second |
Protection | |
Input Impedance | RTD /Volt/Tc> 20 MΩ |
mA 50Ω Shunt External | |
CMRR | >100 dB@ 50, 60 Hz at 3 Sample per Second |
NMRR | >50 dB@ 50, 60 Hz at 3 Samples per Second |
Maximum Common Mode Voltage | 5V AC |
Isolation Channel – EARTH | 1.5KV 1 minute |
Input Protection | 30V AC/DC max |
Termination | Non Interchangeable , Removable Plugs, Individual For Each Input |
Transmitter Power Supply | Non Isolated 15V DC; 30mA max, un protected |
Environmental | |
Temperature | (Operation)5°C to 45°C |
(Limiting) 0°C to 50°C | |
(Storage)-20°C to 60°C | |
Humidity | (Operation) 10 to 80 % RH Non Condensing |
(Storage) 5 to 90 % RH Non Condensing | |
Altitude | <2000 meter |
Power Requirement | |
Supply Voltage (Mains Operated) | 85-264VAC 47-63Hz |
Battery backup | Yes |
DC Adapter Operated | Yes |
Power | 15W Max With Maximum Configuration |
Fuse Type | None |
Battery Backup | |
Battery | 12V 7Ah External Lead Acid battery |
Battery Charger | Yes |
Battery Reverse Polarity | Protected |
Minimum Back up | >12 Hrs up to 2 Pen recorder |
Communication RS232 / 485* | |
Protocol | Proprietary |
Baud Rate | 4800 |
Parity | None |
Relay Output | |
No of Output Channel Per Board | 6 Max |
Output Type | Potential free contact; 1 Form C |
Configuration | High/Low/High-Low/On-Off (Hysteresis band settable) |
Life expectancy | Mechanical:10^7 operations |
Electrical: 10^5 operations | |
Load | 1A, 230VAC resistive |
Relay refresh rate | 1Sec |
Isolation Relay – Relay | 2.5 KV 1 Minute |
Isolation Relay Contact – GND | 1.5 KV 1 Minute |
Safety | |
Safety | IEC 61010-1 |
EMI-EMC | EN 61326-1 Class B |
Pollution Degree | II |
Installation Category | IV |
Vibration | 2g Peak (10 Hz-150Hz) |
Shock | IEC61010-1 |
IP Rating | IP50 (Door and Bezel only) |
Overall Dimension | |
Dimension L x W x D (mm) | 160x160x280 |
Panel Cutout (mm) (L x W) | 138×138 |
Bezel (mm) | 160×160 |
Input Type | Valid Input Range | Resolution Chart | Accuracy | Display Range |
PT-100(RTD)# | -100 to +600°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
mA | 4-20mA/0-20mA | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
mV | -1000.0 to +1000.0 | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-J(Fe-CuCn) | 0 to 400°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-K (NiCr-NiAl) | 0 to 1200°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-R(Pt13Rh-Pt) | 0 to 1750°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-S(Pt10Rh-Pt) | 0 to 1750°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-T(CU-CuCn) | -100 to +400°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
Sr. No. | Range** | Speed | Part No. | Part Description |
81 | 0 to +100 | 20mm/Hr | 311002 | STC Roll 0100 |
82 | 0 to +150 | 20mm/Hr | 311008 | STC Roll 0150 |
83 | 0 to +1200 | 20mm/Hr | 311007 | STC Roll 01200 |
84 | -50 to +50 | 20mm/Hr | 311015 | STC Roll -5050 |
99 | Other Please Specify |
** First value in the chart is at the center of the Chart.
# PS: Pressure Sensitive Chart.
Specification listed are for each of the modules that can be fitted. Refer to the order code for the exact modules fitted in your system. Specifications for the modules that are not fitted, will not be applicable. Specifications are subject to change without notice
±0.5%FSD±1 Digit |
Accessories
1) Charts: 1 Roll 10mtr in length, 100mm calibrated radius.
(As Per Your Given Range in Table)
Sr. No. | Range** | Speed | Part No. | Part Description |
81 | 0 to +100 | 20mm/Hr | 311002 | STC Roll 0100 |
82 | 0 to +150 | 20mm/Hr | 311008 | STC Roll 0150 |
83 | 0 to +1200 | 20mm/Hr | 311007 | STC Roll 01200 |
84 | -50 to +50 | 20mm/Hr | 311015 | STC Roll -5050 |
99 | Other Please Specify |
2) Panel Mounting Clamps: 1 Pair: Part No. –206029
3) Pen: 1 Nos.
Pen 1 – Red; Part No. – 217007
Pen 2 – Green; Part No. – 217008
Pen 3 – Blue; Part No. – 217009
Accessories
- 100mm chart Width
- One to Three Analog Input channels
- Universal Power Supply 85-264 V AC, 43-65 Hz
- Other power supply inputs on request
- Direct Input standard Pt-100 / Thermocouple sensors
- Process Input through 4-20mA /0-20mA / 0-1V
- 10-3600 mm/hr of chart speed
- Other chart speed available on request
Pens | |
No. of Pens | 1/2 |
Pen Marking | Continuous |
Pen Response Time | <5Sec (Full Scale) |
Pen Resolution | Stepper Motor Controlled better than 0.1% FSD |
Overshoot | None |
Chart | |
Chart Speed | 10 mm/ hour to 3600mm/hour |
Chart Calibrated Radius/Size | 100mm |
Chart Ranges | Standard (Refer Table 2) / Customized* |
Display, Operator Panels and Input | |
Display Type | Digital, 8 digit ultra-bright LED Numeric / semi alphabetic |
Display Height | 0.3” |
Status Indicator | Channel number and corresponding parameter values, prompts and messages displayed for ease of setup and programming. |
Panel Keys | Front panel KB consisting of 3 keys for programming and calibration |
Analog Input | RTD PT-100 / 4-20mA (External Shunt Resistance of 50 Ω 0.1%) / TCJ-K-R-S-T/ 0-1V |
Sensor Type and Range | Refer to the Table 1 |
Scan Rate | Continuous 1 reading per second |
Protection | |
Input Impedance | RTD /Volt/Tc> 20 MΩ |
mA 50Ω Shunt External | |
CMRR | >100 dB@ 50, 60 Hz at 3 Sample per Second |
NMRR | >50 dB@ 50, 60 Hz at 3 Samples per Second |
Maximum Common Mode Voltage | 5V AC |
Isolation Channel – EARTH | 1.5KV 1 minute |
Input Protection | 30V AC/DC max |
Termination | Non Interchangeable , Removable Plugs, Individual For Each Input |
Transmitter Power Supply | Non Isolated 15V DC; 30mA max, un protected |
Environmental | |
Temperature | (Operation)5°C to 45°C |
(Limiting) 0°C to 50°C | |
(Storage)-20°C to 60°C | |
Humidity | (Operation) 10 to 80 % RH Non Condensing |
(Storage) 5 to 90 % RH Non Condensing | |
Altitude | <2000 meter |
Power Requirement | |
Supply Voltage (Mains Operated) | 85-264VAC 47-63Hz |
Battery backup | Yes |
DC Adapter Operated | Yes |
Power | 15W Max With Maximum Configuration |
Fuse Type | None |
Battery Backup | |
Battery | 12V 7Ah External Lead Acid battery |
Battery Charger | Yes |
Battery Reverse Polarity | Protected |
Minimum Back up | >12 Hrs up to 2 Pen recorder |
Communication RS232 / 485* | |
Protocol | Proprietary |
Baud Rate | 4800 |
Parity | None |
Relay Output | |
No of Output Channel Per Board | 6 Max |
Output Type | Potential free contact; 1 Form C |
Configuration | High/Low/High-Low/On-Off (Hysteresis band settable) |
Life expectancy | Mechanical:10^7 operations |
Electrical: 10^5 operations | |
Load | 1A, 230VAC resistive |
Relay refresh rate | 1Sec |
Isolation Relay – Relay | 2.5 KV 1 Minute |
Isolation Relay Contact – GND | 1.5 KV 1 Minute |
Safety | |
Safety | IEC 61010-1 |
EMI-EMC | EN 61326-1 Class B |
Pollution Degree | II |
Installation Category | IV |
Vibration | 2g Peak (10 Hz-150Hz) |
Shock | IEC61010-1 |
IP Rating | IP50 (Door and Bezel only) |
Overall Dimension | |
Dimension L x W x D (mm) | 160x160x280 |
Panel Cutout (mm) (L x W) | 138×138 |
Bezel (mm) | 160×160 |
Input Type | Valid Input Range | Resolution Chart | Accuracy | Display Range |
PT-100(RTD)# | -100 to +600°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
mA | 4-20mA/0-20mA | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
mV | -1000.0 to +1000.0 | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-J(Fe-CuCn) | 0 to 400°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-K (NiCr-NiAl) | 0 to 1200°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-R(Pt13Rh-Pt) | 0 to 1750°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-S(Pt10Rh-Pt) | 0 to 1750°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
TC-T(CU-CuCn) | -100 to +400°C | 0.1 | ±0.5%FSD±1 Digit | -2000.0 to 2000.0 |
Sr. No. | Range** | Speed | Part No. | Part Description |
81 | 0 to +100 | 20mm/Hr | 311002 | STC Roll 0100 |
82 | 0 to +150 | 20mm/Hr | 311008 | STC Roll 0150 |
83 | 0 to +1200 | 20mm/Hr | 311007 | STC Roll 01200 |
84 | -50 to +50 | 20mm/Hr | 311015 | STC Roll -5050 |
99 | Other Please Specify |
** First value in the chart is at the center of the Chart.
# PS: Pressure Sensitive Chart.
Specification listed are for each of the modules that can be fitted. Refer to the order code for the exact modules fitted in your system. Specifications for the modules that are not fitted, will not be applicable. Specifications are subject to change without notice
±0.5%FSD±1 Digit |
Accessories
1) Charts: 1 Roll 10mtr in length, 100mm calibrated radius.
(As Per Your Given Range in Table)
Sr. No. | Range** | Speed | Part No. | Part Description |
81 | 0 to +100 | 20mm/Hr | 311002 | STC Roll 0100 |
82 | 0 to +150 | 20mm/Hr | 311008 | STC Roll 0150 |
83 | 0 to +1200 | 20mm/Hr | 311007 | STC Roll 01200 |
84 | -50 to +50 | 20mm/Hr | 311015 | STC Roll -5050 |
99 | Other Please Specify |
2) Panel Mounting Clamps: 1 Pair: Part No. –206029
3) Pen: 1 Nos.
Pen 1 – Red; Part No. – 217007
Pen 2 – Green; Part No. – 217008
Pen 3 – Blue; Part No. – 217009