Circular Chart Recorder
– CR6″ No Display

CR2010 series of circular chart recorders are available in 3 different sizes of the charts i.e. 4”, 6” and 11”. If you want better readability in small space, this 6” chart recorder is a perfect fit. These recorders are widely used in low temperature equipment, blood banks, incubators and any more places. It takes direct inputs from RTD Pt-100 / process inputs like 4-20mA. Standard chart speed available are 4Hr/ Rev; 24 Hr/ Rev and 168 Hr / Rev (7Days/ Rev). These recorders are microcontroller based. Crystal controlled chart drive ensures accurate chart speed. Stepper motors for both pen and chart drive, ensures no lag and no backlash. With a cutout of 200 x170 mm and smallest depth, makes it very convenient to use. Transparent polycarbonate door makes the chart visible from distance. They come with universal power supply as a standard feature. Other power supply inputs are also available.

Features

  • 6” Chart Width
  • Single Analog Input channel
  • Direct Input Standard Pt-100 sensors
  • Process Input through 4-20mA
  • No Display
  • Universal Power Supply 85-264 V AC, 47-63 Hz
  • Other power supply inputs on request
  • Battery Back up
  • 4/ 24 / 168 Hrs / Rev of chart Speed
  • Customized chart speed

Specification

Model NoCR2010 Series; 6″ Recorder
Product Code*20×00
Recording System
Pens
No. of Pens1
Pen MarkingContinuous
Pen Response Time< 5 Sec (Full Scale)
Pen ResolutionStepper Motor Controlled, better than 0.1% FSD
OvershootNone
Chart
Chart Speed7 days/rev; 24Hr/Rev and 4H/Rev
Chart Calibrated Radius2.3″ (approx. 59mm)
Chart RangesStandard (Refer Table 2) / Customized (Please specify)
Display, Operator Panels, and Input
Display TypeNone
Status IndicatorLED
Panel KeysFront panel KB consisting of 2 keys for programming and calibration
Analog InputRTD PT-100 / 4-20 mA (External shunt resistance of 50 Ohm ±0.1%)
Sensor Type and RangeRefer to Table 1
Scan RateContinuous, 1 reading per second
Protection
RTD Input Impedance> 20 MΩ
Volt InputN/A
mA Input50Ω / 2.7Ω Shunt External
CMRR> 100 dB @ 50, 60 Hz at 3 Samples per Second
NMRR> 50 dB @ 50, 60 Hz at 3 Samples per Second
Maximum Common Mode Voltage5V AC
Environmental
Temperature (Operation)5˚C to 45˚C
Temperature (Limiting)0˚C to 50˚C
Temperature (Storage)-20˚C to 60˚C
Humidity (Operation)10% to 80% RH (Non-Condensing)
Humidity (Storage)5% to 90% RH (Non-Condensing)
Altitude< 2000 meters

Table 1: Sensor Type, Range, Accuracy and Max Error Specification

Input TypeValid Input RangeResolution ChartAccuracyLinearization Error (Max)
PT-100 (RTD)-200 to +850˚C2%+/- 0.5% FSD±0.7˚C Max
mA4-20 mA2%+/- 0.5% FSD± 0.1% Max

Table 2: Standard Available Chart Ranges

Sr. No.Range**SpeedSizePart No.Part Description
210 to 10024H6”304001D60100
220 to 15024H6”304002D60150
230 to 20024H6”304005D60200
240 to 30024H6”304007D60300
25-50 to +507 Day6”305005W6-50+50
26-100 to +10024H6”306005D6-100+100
27-200 to +2007 Day6”307005W6-200+200
28-50 to +15024H6”308005D6-50+150
290 to 1007 Day6”309005W6-0+100
30-75 to +7524H6”310005D6-75+75
31-100 to +507 Day6”307005W6-100+50
32+50 to -1007 Day6”307008W650-100
33+40 to -107 Day6”307007W640-10
340 to +507 Day6”307004W6050
350 to 107D6”307012W6010
36+20 to -10 (PS)7D6”308009W620-10PS
37+50 to -100 (PS)7D6”308008W650-100PS
38-50 to +50 (PS)7D6”308005W6-5050PS
39+40 to -10 (PS)7D6”308003W640-10PS
40-50 to +50 (PS)7D6”210042W6-5050PS
50Other Please Specify

** First value in the chart is at the center of the Chart.
# PS: Pressure Sensitive Chart

 

Specification listed are for each of the modules that can be fitted. Refer to the order code for the exact modules fitted in your system. Specifications for the modules that are not fitted, will not be applicable.

Accessories

1) Charts: 100Nos. 

2) Panel Mounting Clamps: 2 Nos.; Part No. – 210034

3) Pen: 5 Nos. (Red Pen); Part No. – 217006

Downloads

    Inquire Now

    TOP