Thermal Calibration
We are a NABL accredited calibration laboratory as per international standard ISO/IEC 17025: 2017. Our laboratory is equipped to do calibration services for temperature & humidity devices.
Temperature and humidity are two very crucial parameters for sensitive products like vaccines, pharmaceuticals, petrochemicals, food processing, etc. It is very crucial that these parameters are measured and maintained during the entire chain of process till the last mile delivery. Calibration of these devices assures confidence in the process and also helps meet the regulatory requirements.
We provide thermal calibration services for temperature & humidity sensors with or without indicators, RTD Sensors, any thermocouple type sensor, temperature gauges, temperature data loggers, thermo hygrometers, temperature & humidity indicating devices, and data loggers.
Features
Key Features:
Calibrate up to
- Temperature Sensors (RTD / Thermocouple): -95 to 1200 °C
- Temperature Data loggers: -30 to 50°C
- Temperature & Humidity Data loggers: 15% to 90% RH & 10 to 50 °C
- Thermo Hygrometer: 15% to 90% RH & 10 to 50 °C
Specification
S.No | Discipline / Group | Measurand or Reference
Material/Type of instrument or material to be calibrated or measured / Quantity Measured /Instrument |
Calibration or Measurement
Method or procedure |
Measurement range and
additional parameters where applicable (Range and Frequency) |
* Calibration and
Measurement Capability (CMC) (±) |
1 | THERMAL SPECIFIC HEAT & HUMIDITY | Humidity measuring
devices with indicator / thermo hygrometer |
Using Standard
Temp & Rh sensor with indicator, multifunction calibrator, & Chamber; by comparison method |
10 °C to 50 °C
@50% RH |
1.05°C |
2 | THERMAL SPECIFIC HEAT
& HUMIDITY |
Humidity measuring
devices with indicator / thermo hygrometer |
Using Standard
Temp & Rh sensor with indicator, multifunction calibrator, & Chamber; by comparison method |
15 %RH to 90 %RH @25°C | 1.48%RH |
3 | THERMAL TEMPERATURE | Temp. data loggers
with inbuilt sensor (RTD/ THERMISTOR/ thermocouple) |
Using PRT 4-Wire sensor with Indicator
, temperature chamber by comparison method |
-30 °C to 50 °C | 0.86°C |
4 | THERMALTEMPERATURE | Temperature sensor
(RTD/ Thermocouple) and Temperature transmitter with or without indicating Devices |
Using R type TC Sensor with indicator,
multifunction calibrator, Dry block Temperature bath by comparison method |
150 °C to 1200 °C | 2.58°C |
5 | THERMALTEMPERATURE | Temperature sensor
(RTD/ Thermocouple) and Temperature Transmitter With or without indicating Devices |
Using PRT 4-Wire
sensor with indicator, multifunction calibrator, with Dry block Temperature bath by comparison method |
150 °C to 600 °C | 1.17°C |
6 | THERMALTEMPERATURE | Temperature sensor
(RTD/ Thermocouple) and Temperature transmitter with or without indicating Devices |
Using PRT 4-Wire
sensor with indicator, multifunction calibrator, Ultra Cool Drywell bath by comparison method. |
-95 °C to 140 °C | 0.64°C |